DTC DETECTION LOGIC
| DTC | Trouble diagnosis name | DTC detection condition | Possible causes |
| P0847 | Transmission Fluid Pressure Sensor/Switch B Circuit Low | The secondary pressure sensor voltage is
0.09 V or less continuously for 5 seconds or
more under the following diagnosis conditions: - Diagnosis conditions - CVT fluid temperature: −20C (−4F) or more - TCM power supply voltage: More than 11 V |
- Harness or connector
(Secondary pressure sensor circuit is
open or shorted to ground) - Secondary pressure sensor - Control valve assembly |
DTC CONFIRMATION PROCEDURE
1.PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at least 10 seconds, then perform the next test.
>> GO TO 2.
2.CHECK DTC DETECTION
With CONSULT
FLUID TEMP : −19C (−2.2F) or more
With GST
CAUTION: When the ambient temperature is −20C (−4F) or less and the engine is cold, warm up the engine for approximately 5 minutes.
Is "P0847"detected?
YES >> Go to TM "Diagnosis Procedure".
NO >> INSPECTION END
1.CHECK CIRCUIT BETWEEN TCM AND CVT UNIT (PART 1)

Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace malfunctioning parts.
2.CHECK CIRCUIT BETWEEN TCM AND CVT UNIT (PART 2)
Check continuity between TCM harness connector terminals and ground. 
Is the inspection result normal?
YES >> GO TO 3.
NO >> Repair or replace malfunctioning parts.
3.CHECK TCM INPUT SIGNALS

Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI "Intermittent Incident".
NO >> There is malfunction of secondary pressure sensor. Replace transaxle assembly. Refer to TM "Removal and Installation".
P0846 Transmission fluid pressure
SEN/SW BDTC Logic DTC DETECTION LOGIC DTC Trouble diagnosis name DTC detection condition Possible causes P0846 Transmission Fluid Pressure Sensor/Switch B Circuit Range/Per ...
Trunk lid opener actuator
Component Function Check
1.CHECK FUNCTION
Select INTELLIGENT KEY of BCM using CONSULT.
Select TRUNK/GLASS HATCH in ACTIVE TEST mode.
Touch OPEN to check that it works normally.
Is the inspection result normal?
YES >> Trunk lid opener actuator is OK.
NO >> Refer to DLK " ...
Hazard and buzzer reminder does
not operate
Diagnosis Procedure
1.CHECK HAZARD ANSWER BACK SETTING IN WORK SUPPORT
Select INTELLIGENT KEY of BCM using CONSULT.
Select HAZARD ANSWER BACK in WORK SUPPORT mode.
Check the HAZARD ANSWER BACK setting in WORK SUPPORT.
Refer to BCS "INTELLIGENT KEY : CONSULT Function (BCM - INTELLIG ...